Daughtridge Sales Co., Inc.
|
| |
|
|
|
|
|
|
Toll Free: 800-967-7507 • Fax: 252-977-2192
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
US Gauge Bimetal, Digital &
Industrial Thermometers |
|

Model ADJ 3" & 5"
Adjustable Angle
Bimetallic Thermometers
STEM DIAMETER: .25” standard up to 42”
stem; .375”
standard over 42” stem
CONNECTION: 1/2-14 NPT
EXTERNAL RESET: Easy to calibrate by
inserting 1/16” hex
wrench into reset
opening
CONSTRUCTION: 304 stainless steel
external parts and
welded construction;
corrosion resistant to most chemicals
HERMETIC SEAL: Per ASME B40.3,
dustproof and
leakproof
HARNESS: All stainless steel brackets
with screws that
loosen to allow 360º
rotation of head and 180º adjustment
of stem position
BELLOWS: Heavy-duty flexible stainless
steel, hermetically
sealed at case and
connection; protects mechanism that
transfers temperature
DIAL: True anti-parallax dial, easy to
read from any angle,
minimizes reading
errors; anodized aluminum with large
black numbers and graduations
LENS: Glass
BIMETALLIC COIL: Helix coil is silicone
coated on ranges
below 500ºF for
vibration dampening and to maximize
heat
transfer and response time
ACCURACY: ±1% full span per ASME
B40.3 Grade A;
adjustment of the angle
between case and stem may affect
accuracy up to 0.5% of span
(ASME B40.3)
OVER TEMPERATURE LIMITS: Up to
250ºF, 100%; 250º to
550ºF, 50%;
550º to 1000ºF, continuous use up to
800ºF,
intermittent use over 800ºF
PRODUCT DATA SHEETS
|
|

Model BAC 3" & 5"
Back Connected
Bimetallic Thermometers
STEM DIAMETER: .25” standard up to 42”
stem; .375”
standard over 42” stem
CONNECTION: 1/2-14 NPT
EXTERNAL RESET: Easy to calibrate by
inserting 1/16” hex
wrench into reset
opening
CONSTRUCTION: 304 stainless steel
external parts, welded
construction,
corrosion resistant to most chemicals
HERMETIC SEAL: Per ASME B40.3,
dustproof and leakproof
DIAL: True anti-parallax dial, easy to
read from any angle,
minimizes reading
errors; anodized aluminum with large
black
numbers and graduations
LENS: Glass
BIMETALLIC COIL: Helix coil is
silicone coated on ranges
below 500ºF
for vibration dampening and to maximize
heat
transfer and response time
ACCURACY: ±1% full span per ASME
B40.3 Grade A, when
using maximum
or minimum temperature indicator,
accurate
to within 1-1/2% full span
OVER TEMPERATURE LIMITS: Up to
250ºF, 100%; 250º to
550ºF, 50%;
550º to 1000ºF, continuous use up to
800ºF,
intermittent use over 800ºF
PRODUCT DATA SHEETS
|
|

Model BOTC 3" & 5"
Bottom Connected
Bimetallic Thermometers
STEM DIAMETER: .25” standard up to 42”
stem; .375”
standard over 42” stem
CONNECTION: 1/2-14 NPT
EXTERNAL RESET: Easy to calibrate by
inserting hex wrench
into reset opening
CONSTRUCTION: 304 stainless steel
external parts, welded
construction;
corrosion resistant to most chemicals
HERMETIC SEAL: Per ASME B40.3,
dustproof and leakproof
DIAL: True anti-parallax dial, easy to
read from any angle,
minimizes reading
errors; anodized aluminum with large
black
numbers and graduations
LENS: Glass
BIMETALLIC COIL: Helix coil is
silicone coated on ranges
below 500ºF
for vibration dampening and to maximize
heat
transfer and response time
ACCURACY: ±1% full span per ASME
B40.3 Grade A
OVER TEMPERATURE LIMITS: Up to
250ºF, 100%; 250º to
550ºF, 50%;
550º to 1000ºF, continuous use up to
800ºF,
intermittent use over 800ºF
PRODUCT DATA SHEETS
|
|
|
|

Model POC 1" Testing
& Spot Checking
Thermometers
STEM LENGTH: 5” (127 mm)
STEM DIAMETER: .15”
CONNECTION: Recal nut is standard
EXTERNAL RESET: Friction nut design
for easy calibration
CONSTRUCTION: 304 stainless steel
external parts, welded
construction;
corrosion resistant to most chemicals
HERMETIC SEAL: Per ASME B40.3,
dustproof and leakproof
DIAL: Anodized aluminum with large
black numbers and
graduations
LENS: Polycarbonate lens is standard
BIMETALLIC COIL: Helix coil is
silicone coated on ranges
below 500ºF
for vibration dampening and to maximize
heat
transfer and response time
ACCURACY: ±1% full span per ASME
B40.3 Grade A
OVER TEMPERATURE LIMITS: Up to
250ºF, 100%; 250º to
550ºF, 50%;
550º to 1000ºF, continuous use up to 800ºF,
intermittent use over 800ºF
POCKET SHEATH: Standard
STANDARD RANGES:
0-250°F & 50-550°F
PRODUCT DATA SHEETS
|
|

5" Industrial Glass Tube
Themometers
SCALE LENGTH: 5”
CASE: Drawn steel case shell, finished in
white baked
enamel; case fits directly on
the metal bulb shield forming an
integral
assembly
INDICATION: Magnifying glass tube
filled with red liquid;
black temperature
scale printed on white case shell
BULB SHIELD: Steel zinc plated or brass
T-571, Low connection only, scale may be
oriented by
rotation of the bulb within its
shield; insertion length is 1-3/8”
CONNECTION:
T-571: 1/2-14 NPT (LM);
T-572: 1/2-14 NPT (LBM)
PRODUCT DATA SHEETS
|
|
|

Model BACO 2"
Back Connected
Bimetallic Thermometers
STEM DIAMETER: .25” standard up to 42”
stem
CONNECTION: 1/4-18 NPT
EXTERNAL RESET: Easy to calibrate by
loosening the socket
head screw (above
hex connecting nut) with 5/64” hex
wrench
CONSTRUCTION: 304 stainless steel
external parts, welded
construction;
corrosion resistant to most chemicals
HERMETIC SEAL: Per ASME B40.3,
dustproof and leakproof
DIAL: Anodized aluminum with large
black numbers and
graduations
LENS: Glass
BIMETALLIC COIL: Helix coil is
silicone coated on ranges
below 500ºF
for vibration dampening and to maximize
heat
transfer and response time
ACCURACY: ±1% full span per ASME
B40.3 Grade A
OVER TEMPERATURE LIMITS: Up to
250ºF, 100%; 250º to
550ºF, 50%;
550º to 1000ºF, continuous use up to
800ºF,
intermittent use over 800ºF
PRODUCT DATA SHEETS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Series DT-8300 Digital Thermometers
RANGES: Low: -50ºF to 450ºF (-50ºC to 250ºC); High: 400ºF
to 1500ºF (200ºC to 800ºC)
INPUT: Type K thermocouple; supplied by U.S. Gauge
distributor or customer, Type J and E
inputs also available
ACCURACY:
Basic Accuracy: ±1% of full scale (excluding T/C error)
Conformance (to ANSI MC95-1): Low Range: ±2.2ºF (1.2ºC)
from –40ºF to 450ºF
High Range: ±2.7ºF (1.5ºC) from 400ºF to 1500ºF
Cold Junction Compensation And Zero Drift: .08 degrees
(F or C)
Span Drift: .008% of reading/ºF (0.015% of reading/ºC)
Resolution: 1ºF (1ºC)
CALIBRATION ADJUSTMENT: Screw adjust permits
calibration to within 1ºF (1ºC) at any
desired point
OPERATING TEMPERATURES: -13ºF to 160ºF (-25ºC to
72ºC), depending on power supply
SELF-POWERED VERSION: Battery, 8 Size AA: 1-1/2 years
continuous operation, typical.
Note: Ambient temperatures
above 100ºF may shorten battery life
EXTERNALLY-POWERED VERSION: Supply Voltage: 6 to 28 VDC (unregulated)
Supply Current: 0 to 2.5 mA
INTRINSICALLY SAFE (FM APPROVED): Battery powered
models are intrinsically safe,
for Class I, II, and III, Division
1, Groups A, B, C, D, E, and G hazardous locations using
U.S. Gauge battery board (accepts 8 AA batteries, not
included) P/N 156834 and when
installed in accordance
with U.S. Gauge instructions AU-3459-F
External powered models are entity approved for safe
operation in Class I, II, and III,
Division 1, Groups A, B, C, D,
E, and G hazardous locations in accordance with U.S.
Gauge
instructions AU-3459-F
V max = 18.7 V, I max = 150 mA, capacitance equals 0.4 µF,
Li = 0.0 mH
External powered models are also entity approved for safe
operation in Class I, II, and III,
Division 1, Groups C, D, E,
and G hazardous locations in accordance with U.S. Gauge
instructions AU-3459-F
V max = 26.7 V, I max = 150 mA, capacitance equals 0.4 µF,
Li = 0.0 mH
DISPLAY: 3-1/2 digit liquid crystal (LCD) 0.7” high numerals;
update rate once per second;
display blanks out for low
power condition and displays large, negative number when
thermocouple or extension wires are open
HOUSING: NEMA 4X design; 1/4 DIN; 302 stainless steel
with one piece, VALOX front
face/bezel and neoprene
gasket; environmentally sealed with one-way valve for
battery venting
CONNECTIONS: 1/2-14 NPT stainless steel half couple seal
welded to case
PRODUCT DATA SHEETS
|
|
|
|
Right click on the Product Data Links to download the product sheet to your computer. |
|
|
Product Data Sheets require Adobe Acrobat Reader.
Click on the link below to get the lastest version.

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|